Customization: | Available |
---|---|
Phase: | Three Phase |
Type: | Standby |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Wide input voltage | High reliability | Strong adaptability |
It has the widest input voltage range and input frequency window (-45% to + 35% of rated voltage and ±10 % rated frequency) and has passed the harsh power grid test in remote areas of many countries; |
The input terminal is equipped with dual isolation and voltage stabilization function; Internal battery warehouse; |
Strong environmental adaptability; The input and output voltage can be 1:1,3:1, 3:3; Wide adaptability to the power grid; |
Flexible customization | High safety | Smart & energy saving |
Cabinet space can be designed according to battery capacity; The charging part can be customized; The UPS host part can be designed according to the technical requirement of high frequency and industrial frequency; |
The protection level can reach IP55; Powerful and comprehensive protection function; Energy saving and environmental protection; |
Unattended and intelligent monitoring(optional); Air conditioner and fan for heat dissipation(optional); Energy saving; |
MODEL | PR-1K | PR-2K | PR-3K | PR-6K | PR-10K |
Capacity | 1KVA/0.7KW | 2KVA/1.4KW | 3KVA/2.1KW | 6KVA/4.2KW | 10KVA/7KW |
INPUT | |||||
Voltage Range | 115~295VAC (±3VC) | 176~297VAC (±3VC) | |||
Frequency Range | 50HZ(46~54Hz)/60HZ (56-64HZ) | ||||
Soft Start | 0~100%, 5sec | ||||
Power Factor | 0.98 | ||||
OUTPUT | |||||
Voltage | 220/230/240VAC | ||||
Voltage Precision | ±2% | ||||
Frequency Precision | 50/60Hz±0.05Hz | ||||
Power Factor | 0.7/0.8(Optional),standard 0.7 | ||||
Wave Distortion | Linear load<3% ;Non-linear load<6% | ||||
Overload Capability | 110%~150%,for 30 seconds later, transfer to bypass | ||||
>150%, for 200ms later, transfer to bypass; | |||||
When load is normal, it can automatically transfer to normal mode. | |||||
Crest Factor | 3:1 | ||||
Transfer Time | 0ms (line to inverter) | ||||
BATTERY | |||||
DC Voltage | 36VDC | 96VDC | 96VDC | 240VDC | 240VDC |
Charge Current | 4A/8A (optional) | 4A/8A (optional) | 4A/8A (optional) | 4.2A | 4.2A |
Battery Capacity | Optional (Battery type and capacity choose by customer) | ||||
SYSTEM | |||||
Display | LCD+LED | ||||
Interface | RS232, SNMP card (optional), Dry contact (optional) | ||||
IP class | IP55 | ||||
Noise | 50dB(1m away) | ||||
Temperature | -25ºC~55ºC(operation,heater optional) | ||||
Humidity | 0~95% (Non-condensing) | ||||
Altitude | 1500m | ||||
Weight (KG) | 85 | 125 | 125 | 125 | 155 |
Dimension (W*D*H) (mm) | 613*640*954 | 650*753*1227 | 940*940*1770 |