• 12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger
  • 12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger
  • 12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger
  • 12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger
  • 12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger
  • 12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger

12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger

Type: Battery Charger
Charger Type: Grid/PV
Charger Application: Standard Battery
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger pictures & photos
12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger
US $3,890-5,890 / Piece
Min. Order: 1 Piece
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
uXcel Premium
Nominal Voltage
120V
Charger Style
Pulse Charger
Compatible Battery Type
Lead Acid/NiCd/ Lithium
Size
800*800*2000
Certification
RoHS, TUV, CE, Toby
Socket Type
Flexible/ Standard
Recyclable
Recyclable
IP
21
Programmable
Yes
Certificates
CE, En61000, IEC60146
OEM/ODM Service
Yes, Customized Service Available
Transport Package
Cartonbox or Wooden Pallets
Specification
Output voltage 7.2-72V
Trademark
EverExceed
Origin
Shenzhen, China
HS Code
8504409999
Production Capacity
10000

Packaging & Delivery

Package Size
57.00cm * 60.00cm * 189.00cm
Package Gross Weight
519.000kg

Product Description

12-pulse thyristor bridge rectifier & latest advanced digital control technology uXcel Premium range industrial battery charger
Product Description

 

The EverExceed uXcel range industrial battery charger is the flagship charger of EverExceed Industrial Power solutions. It integrates proven design topology with the latest advanced digital control technology to control the thyristor bridge rectifier and provides the most reliable and trouble-free performance in any electrical and industrial environments.

12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger

12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger


Advantages:
12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger

Large LCD display

 

User friendly operation with large LCD display, optional touch screen with the choices of 8 languages ensure easy maintenance and operation.Smart communication and Remote Monitoring

12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger Leading Technology- 6 or 12 phase controlled Thyristor technology

 

The embedded micro-computer controller processes signals 10 times faster than standard analog methods.

12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger

Isolation transformer

 

Multilingual digital graphic display with embedded event log. Full compatibility with lead-acid and nickel- cadmium batteries, sealed or vented.

12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger

High Reliability and High MTBF 

 

Precise adjustable temperature compensation, robust and unique design allows the charger to continuously operate at 40°C ambient temperature on full load. Natural ventilation and cooling are available on most of the cases.


>Flexible maintenance and Reduced MTTR-The design make it easy for front-access to all vital modules modules of the charger

 

>Versatile constant voltage and constant current charging modes

 

>Smart communication and Remote Monitoring through isolated RS232, RS485, Ethernet. Full data logging
 

>Long design life up to 20+years-system design life up to 20+ years in continuous operation under the condition of appropriate maintenance

 

>Enhanced Robustness - Mechanical design to withstand vertical and horizontal acceleration stress up to 0.5g as standard

Features:

12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger 12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger 12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger
Flexibly customized
power solutions to perfectly meet the
specific requirements of customer's industrial applications.
Ruggedized solutions
to withstand harsh environments,
extreme temperatures, humidity, dust and vibrations etc. Up to IP55 protection.
Complete power protection solutions
including switchgear,
DC distribution, monitoring suite.
 
Technical parameters:
OUTPUT
Nominal DC voltage 24/48/110/125/220/240/400
Output voltage range 0-1.5×nominal voltage (adjustable)
Nominal DC current 10-1500A
Output current range 0-1.1×nominal current(adjustable)
Voltage stability ±1% in float mode, input within tolerance
Voltage ripple 1% RMS(with battery connected)
Current Limitation Battery current limitation can be adjusted
Filtering  L-C Filter
Output Protection Short Circuit, NH Fuse and Overvoltage protection

 

OPTIONS
Rectifier Other input voltage
Blocking diode
Surge and Lightning protections
Voltage ripple filter
Battery circuit protection box
Battery Battery reversed polarity detection
Battery low-voltage disconnection contactor (LVD)
Battery room temperature sensor
Battery cabinet / rack
Battery monitoring system
Parallel configurations
System Dropping diodes/DC-DC converter
Earth fault monitoring
Internal cabinet lighting
Anti-condensation heater
Output breaker
Front-panel analog meters/digtal meters
DC distribution
Temparature compensation
AC high and AC low alarm/protection
DC high and DC low alarm/protection
AC fault alarm
LED test function
Other frame colour
Mechanical Up to IP55 external
Plate thickness
Galvanized sheet
Front access maintenance
Top cable entry
Special keylock
Specified cabinet identification (tag, nameplate)
Modbus TCP/IP
Communication modbus RTU(RS485)
DNP3.0 protocol
Volt-free contacts
Transducers 4-20mA
Remote monitoring

 

BATTERY
Type Lead acid or nickel cadmium, vented or recombination and Lithium battery

 

COMMUNICATION
Communication RS232, Modbus RTU

 

GENERAL DATA
Operating temperature 0 to 50 °C
Storage temperature -20 to +70 °C
Relative humidity < 95 % non condensing
Operating altitude 1000 m max without derating
Cooling Fan cooling or Natural cooling according to rating
Efficiency 90% according to rating
External protection IP20
Noise
(at 1m in front of the unit)
55 - 65 dB according to rating
Cabinet color RAL 7035
Dimensions Varying according to ratings & options

 

 

STANDARDS
IEC60146-1-1:2009 Semiconductor converters - Specification of basic requirements
IEC62040-1:2008+AMD1:2013
Uninterruptible power systems (UPS) - Part 1-2: General and safety requirements
 for UPS in restricted access locations
IEC62040-2:2006 Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements
IEC61439-1:2011 Low voltage switchgear and controlgear assemblies - Part 1: General rules
IEC60529:1989+
AMD1:1999
Degrees of protection provided by enclosures (IP Code)
IEC60076-11:2004 Power transformers - Part 11: Dry type transformers

 

 

European Directives
Low voltage directive: 2006/95/EC and 2014/35/EU
EMC directive: 2004/108/EC and 2014/30/EU
CE Mark

Application:
The EverExceed uXcel Premium Rectifier Charger range suits all DC applications requiring a large battery back-up:
  1. Power Transmission and Distribution
  2. Continuous process industries
  3. Oil and Gas and Petrochemical industries
  4. Transportation (rail, metro, tramway)
12-Pulse Thyristor Bridge Rectifier &amp; Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger
12-Pulse Thyristor Bridge Rectifier &amp; Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger
 
Why us?  
Reasons you would prefer to buy this power supply products from us 
Service RMA(24/7 pre-sales and after-sales support),OEM,ODM
Quality Highly reliable quality guaranteed by Varta production equipment, German technology, European raw materials
Warranty Standard 2 years, 5+ years upon request
Price Competitive factory Price! Cut down the cost you paid to the middle man
Professional Founded in 1985, 30+ years battery manufacturing experience
Production capacity 3,500,000KVAh per year
Reliable Two R&D centers;
Three major production bases;
Global 500+ dealers/ agents;
Global 100+ offices;
Business coverage 65+ countries around the world
 
Shipping & Payment
Payment T/T,  L/C , Cash, Western Union etc.(flexible payment term can be discussed)
Port Normally Shenzhen China (any sea port upon request)
Delivery  By sea/air/trian/truck transportation
Delivery time Normally 4 weeks ex factory excluding shipping.
Packing: Pack in carton box then pallet (wooden box)


FAQ:

How are "equalize", "boost" and "fast charge" charging different?
Each of these terms describes the same function of the charger where the charger temporarily elevates the battery's voltage above the float level. There are different uses for elevated charge voltage, as shown below:
Commonly understood meaning of the term
Equalize - Periodic "topping up" of battery capacity, and correct cell capacity differences
Boost - Can refer to "equalize," "fast charge," and sometimes both
Fast charge - Faster recharge of a discharged battery

What does "equalize" charging do, and why is it needed?
All batteries, even those assembled into unitized blocks, are all built of individual battery cells connected in series to obtain the required DC voltage. Like all manufactured products, there is variation between the capacities of each cell in the battery. As the battery ages this variation increases. Since the battery is a chain of cells that is only as strong as the weakest link some scheme is required to ensure that all cells stay at peak capacity.
A scheme called "equalizing" is commonly used in both lead-acid and nickel cadmium batteries. Equalizing temporarily elevates the charging voltage of the entire battery string above the normal "float" voltage. The elevated charging voltage allows all cells, including the weak ones, to accept more current from the charger than they would at float voltage. A consequence of the elevated equalize voltage is that all cells in the battery are overcharged. This is acceptable for short periods provided the battery has sufficient electrolyte.
Overcharging greatly increases the rate at which the water in battery electrolyte is electrolyzed into oxygen and hydrogen gas. Since low electrolyte level will permanently damage the battery it is important to limit when, and for how long, the battery is charged at the equalize voltage.

What is "fast charging"?
Batteries, like all electrical conductors, suffer from resistance in their conductive metals. Ohm's law says that resistance increases in proportion to current flow through the battery (or any other imperfect conductor). This means that the more amperes of charge we attempt to apply to the battery the more will be lost due to internal heating.
"Fast charging" temporarily increases the charger's output voltage to compensate for the battery's internal resistance. This allows the battery to continue accepting maximum current from the charger for a longer time - instead of reducing its charge acceptance early as it would if charged at normal float voltage.

What is the correct charging voltage?
The value of both float and equalize/boost/high rate voltages is determined by the battery manufacturer, and depends on the chemistry and construction of the battery. Deviating from the recommended values, except where needed to adjust for temperature, will under or overcharge the battery - both of which will reduce the battery's life and performance.

How do you know when the charger should operate in float or equalize mode?
Regardless of the intended purpose of increasing the charger's voltage there needs to be a way to start and end charging at voltage higher than float.
The most common control methods are shown below.
Control method: Manual switch
  • Advantage: Simple, cheap
  • Disadvantage: High risk of forgetting unit is operating at elevated charging voltage
  • Comment: Not recommended
Control method: Manually initiated timer
  • Advantage: Simple, and automatically terminates charge
  • Disadvantage: Requires user intervention
  • Comment: No way to know when battery would benefit from elevated voltage charge. No way to know what the right time setting is
Control method: Automatically initiated timer
  • Advantage: Suited for remote sites where users do not visit frequently
  • Disadvantage: Time must be pre-programmed.
  • Comment: The correct pre-programmed time cannot be predicted since depth of discharge is likely to vary
Control method: Automatic initiation with battery-determined end
  • Advantage: Termination of elevated charge voltage is based on battery needs, not a program
  • Disadvantage: High continuous current can trick system into staying at elevated voltage too long
When is battery temperature compensation needed? How important is it?
It is well known that all storage batteries - vented or VRLA lead acid or nickel cadmium - require different charging voltage at different temperatures. When cold, the battery requires higher than normal charge voltage in order to deliver maximum possible performance. When warm, charging voltage must be reduced to prevent overcharging and consequent loss of electrolyte.
When the battery is located in a well-controlled environment temperature compensation adds little value. In contrast, temperature compensation is absolutely essential when batteries are located in outdoor cabinets or other areas subject to extremes of temperature. These facts illustrate the value of temperature compensation:
  • When a battery that is 90 degrees F in temperature is charged at the correct voltage for 50 degrees F it will be boiled dry in three months.
  • When a battery 20 degrees F is charged at the correct voltage for 50 degrees F it will fail to charge - and thus fail to deliver its specified performance.
Using a charger equipped with automatic temperature compensation can prevent both of these problems.


I am thinking about disabling the temperature compensation feature because the charger and battery are not in the same location, and I am worried about overcharging the battery.
Temperature compensation should only be disabled if the batteries can always be guaranteed to be at room temperature (25C, or 77F).
Remote temperature sensing (RTS) is the correct way to provide temperature compensated charging where battery and charger are in different ambients. It is always preferable to both non-compensated and locally compensated charging. Using a sensor attached directly to the battery eliminates all variables of charger temperature and different room temperatures. There is no downside to using RTS. Compared with either disabled, or in-charger temperature compensation, RTS will absolutely, positively increase battery performance to the maximum possible. Regardless of conditions, RTS causes the charger to deliver the exact voltage needed by the battery.
EVEREXCEED made a provision to disable temperature compensation mainly for customer acceptance testing - to demonstrate that the voltage setting agrees with the actual output voltage. This can be difficult to determine in a temperature compensated charger.
EVEREXCEED designed its RTS system so that if the remote sensor is damage or becomes disconnected the charger reverts to non-compensated operation. This change is indicated on the charger front panel.

Why do nickel cadmium batteries need to be "boost" charged?
Nickel cadmium batteries offer the highest reliability of any battery, and are more resistant to mechanical and environmental abuse than lead-acid batteries. They do, however, need special charging in order to deliver maximum performance.
If a nickel cadmium battery is charged only at the float rate it will typically deliver only about 70% of its rated capacity. This is a more serious problem for high rate applications, such as engine starting, where even small reductions in capacity have a significant impact on performance.
The most effective way to insure full capacity is available in a nickel cadmium battery is to periodically charge it at an elevated voltage. This can be initiated either manually or automatically, depending on the charger. Automatic equalization is easier to use, and reduces the risk of forgetting to switch back to float voltage.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger pictures & photos
12-Pulse Thyristor Bridge Rectifier & Latest Advanced Digital Control Technology Uxcel Premium Range Industrial Battery Charger
US $3,890-5,890 / Piece
Min. Order: 1 Piece
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Number of Employees
53
Year of Establishment
2010-04-27