Front Access Terminal AGM FT Telecom 12V 80ah Front Terminal Battery
Product introduction:
The extremely powerful, compact Gel batteries of EverExceed front access FT Gel Range are an absolutely reliable energy source for durability in Solar / Photovoltaic, Telecommunications and Electric Utility applications. These VRLA batteries provide excellent performance and reliability in long duration discharge & cycling applications. Our development team combines the market's demand with design optimization, precision component selection and state of the art manufacturing process to produce the most cost effective battery solution for today's applications.
Technical features:
• Special design complies with telecom 19''/ 23'' cabinet for space limitation;
• The success of EverExceed Gel batteries comes from the internationally superior EverExceed Gel technology;
• Exceptional energy storage capacity combined with long life - BCI Classification;
• Virgin pure Lead Tin and thick positive plate technology design for maximum service life -15 years design life @ 20˚C (68˚F);
• Thickness positive plate plus optimized plate alloy to anti-corrosion;
• Designed in accordance with IEC 60896-21/-22;
• Spill-proof and leak-proof;
• Maintenance-free (no topping up) during the whole service life due to EverExceed GEL technology;
• Flame-arresting one-way pressure-relief vent for safe and long life;
• Microporous rubber and corrugated PVC SiO2 separator, the special design increases the high porosity and anti-corrosion and decrease the internal resistance;
• Electrolyte in solid gel form will not stratify-no equalization charge required;
• Sulfuric acid thixotropic gel, gel powder from Europe leading supplier to ensure the unique performance of gel battery;
• Increased durability and deep cycle ability for heavy-duty applications;
• Fully tank formed grid Lead Calcium Tin plate ensures voltage matching between cells;
• Shelf life up to 2 years at 20˚C (68˚F), very low gassing due to internal gas recombination;
• Unique performance against high temperature;
• Can be used in any orientation. Upright, side or end mounting recommended;
• Reinforced ABS case and cover - flame retardant material UL 94 V-0 on request.
• Proprietary Fixed Orifice Plate pasting technology applying active materials on both sides of the grid for consistent cell-to-cell performance, higher capacity and uniform grid protection.
Technical Data:
Battery Model |
Nom. Voltage (V) |
Capacity C10 1.80VPC |
Short Circuit current Amps |
Internal Resistance Milli-ohms |
Female Terminal Type |
Battery Weight |
Outline Dimensions |
Length |
Width |
Height |
Kg |
lbs |
mm |
inch |
mm |
inch |
mm |
inch |
FT12V80G |
12 |
80 |
1880 |
6.32 |
F-M6 |
33.5 |
73.7 |
395 |
15.6 |
110 |
4.33 |
285 |
11.2 |
FT12V100G |
12 |
100 |
2326 |
5.27 |
F-M6 |
35 |
77 |
510 |
20.1 |
110 |
4.33 |
225 |
8.86 |
FT12V155G |
12 |
155 |
3141 |
4.23 |
F-M8 |
59.5 |
131 |
560 |
22 |
125 |
4.92 |
316 |
12.4 |
FT12V180G |
12 |
180 |
4176 |
3.85 |
F-M8 |
65 |
143 |
560 |
22 |
125 |
4.92 |
316 |
12.4 |
Applications:
• Telecommunications
• Solar/ Photovoltaic
• UPS
• Wind Generations
• RV/ Marine
• Remote monitoring
• Lighting
• Golf cart
• Cathodic protection
Why us? |
|
Reasons you would prefer to buy this power supply products from us |
Service |
RMA(24/7 pre-sales and after-sales support),OEM,ODM |
Quality |
Highly reliable quality guaranteed by Varta production equipment, German technology, European raw materials |
Warranty |
Standard 2 years, 5+ years upon request |
Price |
Competitive factory Price! Cut down the cost you paid to the middle man |
Professional |
Founded in 1985, 30+ years battery manufacturing experience |
Production capacity |
3,500,000KVAh per year |
Reliable |
Two R&D centers;
Three major production bases;
Global 500+ dealers/ agents;
Global 100+ offices;
Business coverage 65+ countries around the world |
Shipping & Payment |
Payment |
T/T, L/C , Cash, Western Union etc.(flexible payment term can be discussed) |
Port |
Normally Shenzhen China (any sea port upon request) |
Delivery |
By sea/air/trian/truck transportation |
Delivery time |
Normally 4 weeks ex factory excluding shipping. |
Packing: |
Pack in carton box then pallet (wooden box) |
EVEREXCEED BATTERY FAQ:
Ø Q1. Can your battery be delivered by sea and air?
A: Yes, our batteries can be delivered both by sea and by air. We have MSDS, test report for safe transport as non-dangerous products.
Ø Q2. Can I put my logo on the battery?
A: Yes, you can print your logo on our batteries Freely.Welcome to share us your logo design.
Ø Q3. Can I fast charge my battery?
A: Fast charging is not recommended as ifs harmful for the battery.
ØQ4. Can I do a partial replacement of my batteries?
A: Partial battery replacement of lead acid battery banks is not recommended.
Ø Q5. How about your delivery time usually?
A: About 7 days for stock products, around 20 days for half container products, 30 days for 20ft full container products.
Ø Q6. Are you a battery manufacturer, and do you produce the plate by yourself ?
A: Yes, we are a professional battery manufacture in Guangdong Province, China. And we produce plates by ourselves.
Ø Q7. What certificate your company have?
A: ISO 9001, ISO 14001, OHSAS 18001, CE, UL, IEC 61427 test report, Patent for gel technology and other Chinese honor.
Ø Q8.What is your warranty time for VRLA battery ?
A: It depends on battery capacity, depth of discharge, and battery usage. Please kindly contact us for accurate information based on detailed requirements.
Ø Q9. Why battery has different capacity at different hour rate?
A: The capacity of a battery, in Ahs, is a dynamic number that is dependent on the discharge current. For example, a battery that is discharged at 10A will give you more capacity than a battery that is discharged at 100A. With the 20-hr rate, the battery is able to deliver more Ahs than with the 2-hr rate because the 20-hr rate uses a lower discharge current than the 2-hr rate.
Ø Q10. What is the shelf life of VRLA battery and how to maintain the battery?
A: The limiting factor of battery's shelf life is the rate of self-discharge which itself is temperature dependent. VRLA batteries will self-discharge less than 3% per month at 77° F (25° C). VRLA batteries should not be stored for more than 6 months at 77° F (25° C) without recharged. If in hot temperature, recharge it every 3 month. When batteries are taken out of long storage, it is recommended to recharge before use.
Ø Q11. How does your factory control the quality?A: We Adopt ISO 9001 quality system to control the quality. We have Incoming Quality Control (IQC) department to test and confirm raw material meets high quality producing requirements, Production Quality Control (PQC) department contains The first Inspection, In-process quality control, acceptance inspection and full inspection, Outgoing Quality Control (OQC) department confirm no defective batteries come out from the factory.