Customization: | Available |
---|---|
Type: | Lead-Acid Batteries |
Usage: | Car, Bus, UPS, Electric Power, Lighting, Electric Bicycle, Boat |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
EverExceed AINO MICRO superior valve regulated lead acid (VRLA) rechargeable batteries are designed to provide outstanding performance in withstanding over-charge, over-discharge and resisting vibration and shock. These batteries with compact design, save installation space, while providing full and reliable power. The use of special sealing epoxies, groove case and cover construction and long sealing paths for posts and connectors, assures that the VRLA battery will offer exceptional leak resistance and allows them to be used in any position.
Industry leading | High reliability | Highly compatible with UPS |
AM 12-9 have maximum 36Watt @15mins , AM 12-12 & AM 12-18 have 55Watt @ 15mins & 88Watt @ 15mins power output respectively. | Using special high tin alloys having lowest calcium levels and highest tin levels in the industry-minimizing grid growth, reducing gassing & extending battery life. | Specially designed & manufactured to save installtion space while providing full & reliable power for all kinds of UPS |
Low self-discharge rate | Complete protection | Long service life |
Less than 3% per month discharge at 20°C (68°F) | No matter what the situation, a trustworthy UPS battery guarantees your devices stay powered through anything. | 5~8 years design life @ 20°C(68°F) ambient temperature |
Wide operating temperature range | Long warranty | Advanced technology |
Long lasting high performance in high and low temperatures {-40°C(-40°F) ~ 70°C (-158°F )} | 2 years warranty time which is 2 times higher than the other batteries in market. | AGM technology for up to 99% efficient gas recombination and freedom from electrolyte maintenance. |
Model No. |
Nominal Voltage
(V)
|
Rated Capacity 20hr Rate (Ah) | Outline Dimensions | Terminal Type | ||||
Length (mm/inch) | Width (mm/inch) | Height (mm/inch) | Total Height (mm/inch) | Weight (kg/lbs) | ||||
AM 12-0.8 | 12 | 0.8 | 96/3.78 | 25/0.98 | 62/2.44 | 62/2.44 | 0.35/0.77 | Wire Leads & Plug |
AM 12-1.3 | 12 | 1.3 | 97/3.82 | 43.5/1.71 | 52/2.05 | 58/2.28 | 0.56/1.23 | Faston Tab No. 187 |
AM 12-2.2 | 12 | 2.2 | 178/7.01 | 34/1.34 | 60/2.36 | 66/2.60 | 0.88/1.94 | Faston Tab No. 187 |
AM 12-3.3 | 12 | 3.3 | 134/5.28 | 67/2.64 | 60/2.36 | 66/2.60 | 1.22/2.68 | Faston Tab No. 187 |
AM 12-4.0 | 12 | 4.0 | 90/3.55 | 70/2.76 | 102/4.02 | 107/4.22 | 1.33/2.93 | Faston Tab No. 187 |
AM 12-4.5 | 12 | 4.5 | 90/3.55 | 70/2.76 | 102/4.02 | 107/4.22 | 1.37/3.01 | Faston Tab No. 187 |
AM 12-5 | 12 | 5 | 90/3.55 | 70/2.76 | 102/4.02 | 107/4.22 | 1.52/3.34 | Faston Tab No. 187 |
AM 12-7 | 12 | 7 | 151/5.95 | 65/2.56 | 94/3.70 | 98/3.86 | 2.10/4.62 | Faston Tab No. 187 |
AM 12-7.2 | 12 | 7.2 | 151/5.95 | 65/2.56 | 94/3.70 | 98/3.86 | 2.20/4.84 | Faston Tab No. 187 |
AM12-7.2hr | 12 | 7.2hr | 151/5.95 | 65/2.56 | 94/3.70 | 98/3.86 | 2.25/4.96 | Faston Tab No. 250 |
AM 12-9 | 12 | 9 | 151/5.95 | 65/2.56 | 94/3.70 | 98/3.86 | 2.60/5.73 | Faston Tab No. 250 |
AM 12-12 | 12 | 12 | 151/5.95 | 98/3.86 | 94/3.70 | 100/3.94 | 3.30/7.26 | Faston Tab No. 250 |
AM12-12hr | 12 | 12hr | 151/5.95 | 98/3.86 | 94/3.70 | 100/3.94 | 3.45/7.59 | Faston Tab No. 250 |
AM 12-14 | 12 | 14 | 151/5.95 | 98/3.86 | 94/3.70 | 100/3.94 | 4.00/8.80 | Faston Tab No. 250 |
AM 12-18 | 12 | 18 | 181/7.13 | 76/2.99 | 167/6.58 | 167/6.58 | 5.20/11.4 | F-M5 |
AM 12-20 | 12 | 20 | 181/7.13 | 76/2.99 | 167/6.58 | 167/6.58 | 5.70/12.5 | F-M5 |
AM 12-22 | 12 | 22 | 181/7.13 | 76/2.99 | 167/6.58 | 167/6.58 | 6.00/13.2 | F-M5 |
AM 12-26 | 12 | 26 | 166/6.54 | 175/6.90 | 126/4.96 | 126/4.96 | 7.2/15.8 | F-M5 |
AM 12-28 | 12 | 28 | 166/6.54 | 175/6.90 | 126/4.96 | 126/4.96 | 8.2/16.9 | F-M5 |
• Uninterrupted power supplies.
• Security & Fire alarm systems.
• Laboratory & test equipments.
• Monitoring equipments.
• Telecom Equipments.
• Emergency lighting.
• Power tools.
• Medical equipments.
• Consumer electronics.
• Portable equipments.
• Toys and Hobbies.
• Marine instruments
Why us? | |
Reasons you would prefer to buy this power supply products from us | |
Service | RMA(24/7 pre-sales and after-sales support),OEM,ODM |
Quality | Highly reliable quality guaranteed by Varta production equipment, German technology, European raw materials |
Warranty | Standard 2 years, 5+ years upon request |
Price | Competitive factory Price! Cut down the cost you paid to the middle man |
Professional | Founded in 1985, 30+ years battery manufacturing experience |
Production capacity | 3,500,000KVAh per year |
Reliable | Two R&D centers; Three major production bases; Global 500+ dealers/ agents; Global 100+ offices; Business coverage 65+ countries around the world |
Shipping & Payment | |
Payment | T/T, L/C , Cash, Western Union etc.(flexible payment term can be discussed) |
Port | Normally Shenzhen China (any sea port upon request) |
Delivery | By sea/air/trian/truck transportation |
Delivery time | Normally 4 weeks ex factory excluding shipping. |
Packing: | Pack in carton box then pallet (wooden box) |
1. What's An AGM Battery ?
A.The AGM battery uses fiberglass mats sandwiched between lead plates. It's where the battery gets its name - Absorbent Glass Mat (AGM). The glass mat wicks the electrolyte solution, keeping it suspended in place, so it's not free-flowing. Because the AGM is a sealed battery, there's minimal to no off-gassing. Gases produced during the chemical reaction recombined with the electrolyte. And if there is excess gas (such as when the battery is overcharged), a vent releases it to maintain internal pressure.
B. How AGM vs Lead Acid Batteries Work
The AGM battery and the standard lead acid battery are technically the same when it comes to their base chemistry. They both use lead plates and an electrolyte mix of sulfuric acid and water and have a chemical reaction that produces hydrogen and oxygen as a byproduct.
C. It's used in all types of applications - from marine to off-grid power systems and in advanced vehicles with significant power demands.
2. Maintenance requirements ?
The sealed lead acid battery (SLA battery) is a subset of lead acid batteries. It's also known as a Valve Regulated Lead Acid battery (VRLA battery).
AGM batteries are maintenance free and can be placed in more enclosed areas because there is no exhaust except for occasional exhaust. It is suitable for various application scenarios and places that are difficult to maintain.3. Durability, Vibration And Shock Resistance
The AGM battery tends to be built harder than the flooded lead acid battery, as it originally served military and aviation use.
3. Mounting Flexibility And Spillage ?
The glass mat technology in the AGM battery makes it spill-proof and position insensitive. You can mount it in many configurations (just don't turn it upside down).
4. Internal Resistance and Power Output ?
The AGM battery's internal resistance is among the lowest of the various lead acid batteries. While a new flooded lead acid battery can have an internal resistance of 10-15%, a new AGM battery can be as low as 2%.
5. Charging Time ?
Low internal resistance also grants the AGM battery faster charging times.
6. Drainage depth ?
AGM batteries have an 80% discharge depth (DoD) and can limit their discharge depth to 100% during backup use
7. Temperature Tolerance ?
The AGM battery generally performs better in all temperatures and tends towards good Cold Cranking Amp (CCA) ratings.
The electrolyte that's held in the glass mat doesn't expand like a liquid while frozen. This makes AGM batteries resistant to cold weather damage.
8. Lifespan And Self-Discharge ?
AGM batteries generally last longer than standard lead acid batteries. Because of their low self-discharge rate
9.Can I Use AGM Or Lead Acid Batteries As A Battery Bank?
Yes.
Both the AGM lead acid deep cycle batteries can act as a battery bank and charge up with a solar panel.
An AGM battery bank would be easier to configure because they can lie on their sides.
They're also maintenance-free.