Front Terminal 6V 200ah Front Access VRLA AGM Lead Acid Battery

Product Details
Customization: Available
Type: Lead-Acid Batteries
Usage: UPS, Electric Power, Telecom

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
53
Year of Establishment
2010-04-27
  • Front Terminal 6V 200ah Front Access VRLA AGM Lead Acid Battery
  • Front Terminal 6V 200ah Front Access VRLA AGM Lead Acid Battery
  • Front Terminal 6V 200ah Front Access VRLA AGM Lead Acid Battery
Find Similar Products

Basic Info.

Model NO.
FT6V200
Discharge Rate
High Discharge Rate
Shape
Square Battery
Electrolyte
Acid
Installation
Packaged
Rechargeable
Chargeable
Battery Type
Lead Acid VRLA
Battery Current Capacity
200ah
Certificate
ISO / CE/ Dekra/ IEC
Design Life
15 Years
Battery Color
Black
Transport Package
Cartonbox or Wooden Pallets
Specification
323x125x250mm
Trademark
EverExceed
Origin
Shenzhen, China
HS Code
8507200000
Production Capacity
3500000kah/Year

Product Description

Front Terminal 6v 200ah Front Access VRLA AGM Lead Acid Battery
Front Terminal 6V 200ah Front Access VRLA AGM Lead Acid Battery
Product Introduction:
The EverExceed front access FT Range VRLA provides high performance and reliability in long duration discharge applications.The extremely powerful, compact AGM batteries of EverExceed front access FT Range are an ideal energy source for durability in Telecommunications and Electric Utility applications.


Technical features:
 
 
 
Front Terminal 6V 200ah Front Access VRLA AGM Lead Acid Battery
Front Terminal 6V 200ah Front Access VRLA AGM Lead Acid Battery Front Terminal 6V 200ah Front Access VRLA AGM Lead Acid Battery
High safety Unique performance VRLA recombinant technology
Heavy duty M6 / M8 Female copper plated terminals provide maximum performance and easy installation, reduced maintenance and increased safety
Proprietary Fixed Orifice Plate Pasting technology applying active materials on both sides of the grid for consistent cell-to-cell performance, higher capacity and uniform grid protection.
 

High-Compression Absorbed Glass Mat technology (AGM) for greater than 99% recombination efficiency.

     
Front Terminal 6V 200ah Front Access VRLA AGM Lead Acid Battery Front Terminal 6V 200ah Front Access VRLA AGM Lead Acid Battery Front Terminal 6V 200ah Front Access VRLA AGM Lead Acid Battery
Wide operating temperature range Easy installation Long service life
-40°C to +70°C Multicell design for ease of installation and maintenance Thick positive plate design for maximum service float life- 12 years design life @ 20°C(68°F).
     
Full front maintenance
Assured quality Space saving
Special front access design comply with telecom 19"/ 23" cabinet These industry leading rechargeable batteries are approved with UL1989, CE, IEC60896, IEC61427 Compact & lightweight for space limitation in UPS & telecom applications

Technical Data:
Battery Model Nominal Voltage (V) 15 min. WPC 1.67VPC@ 20°C Capacity C10 1.80VPC @ 20°C Capacity C8 1.75VPC @ 20°C Short Circuit Current Amps Internal Resistance Milliohms Female Terminal Type Battery Weight (kg/lb) Outline Dimensions (mm/inch)
Length Width Height
FT6V200 6 619 200 198 3500 1.8 F-M8 34.5 75.9 363 14.3 125 4.92 250 9.84
FT12V55 12 168 55 54.5 1600 6.5 F-M6 17.3 38.1 280 11 105 4.13 225 8.86
FT12V75 12 227 75 74.3 2300 5.4 F-M6 26.5 58.3 560 22 115 4.53 185 7.28
FT12V80 12 244 80 79.2 2450 5.1 F-M8 28 61.6 395 15.6 110 4.33 285 11.2
FT12V100A 12 320 103 102 3000 4.7 F-M8 34 74.8 395 15.6 110 4.33 285 11.2
FT12V100B 12 305 100 99.2 2950 4.9 F-M8 31 68.2 395 15.6 110 4.33 285 11.2
FT12V110 12 333 110 109 3150 4.6 F-M8 32 70.4 510 20.1 110 4.33 225 8.86
FT12V120A 12 375 124 122 3350 4.4 F-M8 34.5 75.9 395 15.6 110 4.33 285 11.2
FT12V120B 12 363 120 119 3200 4.5 F-M8 32 70.4 550 21.7 110 4.33 240 9.45
FT12V150 12 464 150 149 3680 4 F-M8 44 96.8 550 21.7 110 4.33 285 11.2
FT12V155A 12 495 160 157 3800 3.7 F-M8 49 108 550 21.7 110 4.33 285 11.2
FT12V155B 12 480 154 153 3700 3.8 F-M8 47 103 550 21.7 110 4.33 285 11.2
FT12V170 12 526 170 168 4200 3.5 F-M8 52 114 560 22 125 4.92 316 12.4
FT12V180A 12 574 185 184 4500 3.3 F-M8 58 128 560 22 125 4.92 316 12.4
FT12V180B 12 557 180 178 4200 3.4 F-M8 53 117 560 22 125 4.92 316 12.4
FT12V190 12 588 190 188 4800 3.2 F-M8 59 130 560 22 125 4.92 316 12.4
FT12V200 12 619 200 198 5000 3 F-M8 59.5 131 560 22 125 4.92 316 12.4



Applications:
Telecommunications
Distributed Power
Cellular Radio
Broadband
UPS
Switchgear Control Power

Front Terminal 6V 200ah Front Access VRLA AGM Lead Acid Battery

Front Terminal 6V 200ah Front Access VRLA AGM Lead Acid Battery
Why us?  
Reasons you would prefer to buy this power supply products from us
Service RMA(24/7 pre-sales and after-sales support),OEM,ODM
Quality Highly reliable quality guaranteed by Varta production equipment, German technology, European raw materials
Warranty Standard 2 years, 5+ years upon request
Price Competitive factory Price! Cut down the cost you paid to the middle man
Professional Founded in 1985, 30+ years battery manufacturing experience
Production capacity 3,500,000KVAh per year
Reliable Two R&D centers;
Three major production bases;
Global 500+ dealers/ agents;
Global 100+ offices;
Business coverage 65+ countries around the world
Shipping & Payment
Payment T/T, L/C , Cash, Western Union etc.(flexible payment term can be discussed)
Port Normally Shenzhen China (any sea port upon request)
Delivery By sea/air/trian/truck transportation
Delivery time Normally 4 weeks ex factory excluding shipping.
Packing: Pack in carton box then pallet (wooden box)
Front Terminal 6V 200ah Front Access VRLA AGM Lead Acid BatteryFront Terminal 6V 200ah Front Access VRLA AGM Lead Acid BatteryFAQ:
Ø Q1. Can your battery be delivered by sea and air?
A: Yes, our batteries can be delivered both by sea and by air. We have MSDS, test report for safe transport as non-dangerous products.
Ø Q2. Can I put my logo on the battery?
A: Yes, you can print your logo on our batteries when you order reach 20ft container quantity. If not, price will be negotiated.
Ø Q3. Can I fast charge my battery?
A: Fast charging is not recommended as ifs harmful for the battery.
ØQ4. Can I do a partial replacement of my batteries?
A: Partial battery replacement of lead acid battery banks is not recommended.
Ø Q5. How about your delivery time usually?
A: About 7 days for stock products, around 20 days for half container products, 30 days for 20ft full container products.
Ø Q6. Are you a battery manufacturer, and do you produce the plate by yourself ?
A: Yes, we are a professional battery manufacture in Guangdong Province, China. And we produce plates by ourselves.
Ø Q7. What certificate your company have?
A: ISO 9001, ISO 14001, OHSAS 18001, CE, UL, IEC 61427 test report, Patent for gel technology and other Chinese honor.
Ø Q8.What is your warranty time for VRLA battery ?
A: It depends on battery capacity, depth of discharge, and battery usage. Please kindly contact us for accurate information based on detailed requirements.
Ø Q9. Why battery has different capacity at different hour rate?
A: The capacity of a battery, in Ahs, is a dynamic number that is dependent on the discharge current. For example, a battery that is discharged at 10A will give you more capacity than a battery that is discharged at 100A. With the 20-hr rate, the battery is able to deliver more Ahs than with the 2-hr rate because the 20-hr rate uses a lower discharge current than the 2-hr rate.
Ø Q10. What is the shelf life of VRLA battery and how to maintain the battery?
A: The limiting factor of battery's shelf life is the rate of self-discharge which itself is temperature dependent. VRLA batteries will self-discharge less than 3% per month at 77° F (25° C). VRLA batteries should not be stored for more than 6 months at 77° F (25° C) without recharged. If in hot temperature, recharge it every 3 month. When batteries are taken out of long storage, it is recommended to recharge before use.
Ø Q11. How does your factory control the quality?
A: We Adopt ISO 9001 quality system to control the quality. We have Incoming Quality Control (IQC) department to test and confirm raw material meets high quality producing requirements, Production Quality Control (PQC) department contains The first Inspection, In-process quality control, acceptance inspection and full inspection, Outgoing Quality Control (OQC) department confirm no defective batteries come out from the factory.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier