Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | Standby |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1-3KVA PL3 RM Series High Frequency Online UPS
1KVA/ 2KVA/ 3KVA module, 100/110/115/120/127VAC, 1:1
PowerLead3 series power supply adopts online double conversion design and digital control technology and it features high input and output power factor, self-adaptive output frequency according to input frequency,intelligent battery management and excellent network management.
Technical specifications:
MODEL
(Low voltage version)
|
PL3 RM1KS | PL3 RM1KL | PL3 RM2KS | PL3 RM2KL | PL3 RM3KS | PL3 RM3KL |
Capacity | 1kVA/1kW | 1kVA/1kW | 2kVA/2kW | 2kVA/2kW | 3kVA/3kW | 3kVA/3kW |
Phase | 1 Phase in/1 Phase out | |||||
INPUT | ||||||
Nominal Voltage | 100/110/115/120/127VAC (L-N Voltage), L+N+PE | |||||
Input Voltage Range | 85~155VAC (L-N Voltage)@100%load; 85~55VAC, linearly derating from 100% to 50% load | |||||
Input Frequency Range | 50/60±6Hz | |||||
Input Power Factor | >0.99 | |||||
Input Current Distortion (THDi) | <4% | |||||
Bypass Voltage Range | -40%~20% of nominal voltage, adjustable | |||||
OUTPUT | ||||||
Nominal Votage | 100/110/115/120/127VAC (L-N Voltage), L+N+PE | |||||
Voltage Regulation | ± 1 % | |||||
Nominal Frequency | 50/60Hz, adjustable | |||||
Output Frequency | Line Mode:50/60±1/2/3/4/5/6Hz , adjustable ; Battery Mode: 50/60±0.001 Hz | |||||
Output Power Factor | 1 | |||||
Output Voltage Distortion (THDu) | ≤3%@linear load; ≤5%@non-linear load | |||||
Transfer Time |
Line mode to Battery mode, 0ms; Inverter to Bypass, 4ms (Synchronized);
Bypass to Inverter, 4ms(Synchronized); ECO to Battery Mode, 6ms (Typical Time)
|
|||||
Crest Ratio | 3:1 | |||||
Overload Capacity
(Line Mode)
|
10 min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
200 ms @ >150% load
|
|||||
Overload Capacity (Battery Mode) |
1 min @ 102%~110% load;
10s @ 110%~130% load;
3s @130%~150% load;
200 ms @ >150% load
|
|||||
Overload Capacity (Bypass Mode) | Depending the input breaker (20A) | Depending the input breaker (20A) | Depending the input breaker (40A) | Depending the input breaker (40A) | Depending the input breaker (40A) | Depending the input breaker (40A) |
Output Short Circuit Protection | Line Mode: Current limitation; Battery Mode: Current limitation; Bypas Mode: Breaker | |||||
BATTERY | ||||||
Battery Type | Sealed Lead Acid Maintanance Free (VRLA) | |||||
Nominal Voltage | 24VDC | 36VDC | 48VDC | 72VDC | 72VDC | 96VDC |
Charging Voltage | Floating Charge, 2.25V/cell; Boost Charge, 2.35V/cell | |||||
Battery Number&Capacity | 2 pcs, 12V/9Ah | External | 4 pcs, 12V/9Ah | External | 8 pcs, 12V/9Ah | External |
Charging Current | 1A | 1~12A, adjustable | 1A | 1~12A, adjustable | 1A | 1~12A, adjustable |
Charging Mode | Two Satges (CC/Floating) or Three Stages (CC/CV/Floating, settable) | |||||
Typical Recharge Time | 9 hours recharge to 90% | Depending on the capacity of external batteries | 9 hours recharge to 90% | Depending on the capacity of external batteries | 9 hours recharge to 90% | Depending on the capacity of external batteries |
Battery Protection |
Battery Leakage<500µA, Over Voltage Protection, Under Voltage Protection, Over Current Protection;
Battery Deep Discharge Protection
|
|||||
EFFICIENCY | ||||||
Line Mode | 93.5% (Max) | 93.5% (Max) | ||||
Battery Mode | 89.5% (Max) | 90.5% (Max) | 92.5% (Max) | 93.5% (Max) | 92.5% (Max) | 93.5% (Max) |
ECO Mode | 98% | |||||
INDICATORS | ||||||
LCD Panel | UPS status, Battery Level, Load Level, Input/Outpt/Battery Voltage, Fault&Alarm Code | |||||
Audible Alarm | Utility Failure, Battery Voltage Low, Overload, System Fault | |||||
MANAGEMENT | ||||||
Interface | RS232 ,USB, EPO Port, SNMP Card (Optional), Relay Card (Optional) | |||||
ENVIRONMENT | ||||||
Operating Temperature | 0~40ºC | |||||
Operating Humidity | 0~95% RH, non-condensing | |||||
Storage Temperature | -15~60ºC (Battery: 0-40ºC) | |||||
Altitude | <1000m, derating 1% per 100m from 1000~ 2000m | |||||
Noise (1Meter Away) | <50dB | |||||
PHYSICAL | ||||||
Dimension
(W*D*H, unit:mm)
|
440*425*86 | 440*588*86 | 440*470*86 | 440*733*86 | 440*470*86 | |
Net Weight (kg) | 9/11.3 | 4.5 | 19/23.6 | 10 | 25/29.6 | 11 |
Color | Black ( RAL9004) | |||||
STANDARDS | ||||||
Safety | IEC 62040-1:2017 | |||||
EMC | IEC 62040-2:2018 | |||||
Performance | IEC 62040-3:2011 | |||||
Battery | IEC 60896-22:2004 |
Applications:
Shipping & Payment | |
Payment | T/T, L/C , Cash, Western Union etc.(flexible payment term can be discussed) |
Port | Normally Shenzhen China (any sea port upon request) |
Delivery | By sea/air/trian/truck transportation |
Delivery time | Normally 4 weeks ex factory excluding shipping. |
Packing: | Pack in carton box then pallet (wooden box) |