Technical Data(220VAC output)
Technical Data (220VAC OUTPUT): | ||||||||||
MODEL(HV) | RMI1000 | RMI2000 | RMI3000 | RMI4000 | RMI5000 | RMI6000 | RMI8000 | RMI10000 | ||
24V Allowable range of input DC voltage | Cutoff voltage: ≤ 20Vdc, or ≥30Vdc Startup voltage: 22Vdc-28Vdc | |||||||||
48V Allowable range of input DC voltage | Cutoff voltage: ≤ 40Vdc, or ≥60Vdc Startup voltage: 45.5Vdc-57Vdc | |||||||||
110V Allowable range of input DC voltage | Cutoff voltage: ≤ 90Vdc, or ≥135Vdc Startup voltage: 104Vdc-131Vdc | |||||||||
220V Allowable range of input DC voltage | Cutoff voltage: ≤ 180Vdc, or ≥275Vdc Startup voltage: 208Vdc-260Vdc | |||||||||
24V DC Input | Maximum | 42A | 83A | 125A | - | - | - | - | - | |
48V DC Input | current | 21A | 42A | 63A | 83A | 104A | 125A | 167A | 208A | |
110V DC Input | 9A | 18A | 27A | 36A | 45A | 55A | 72.7A | 90.9A | ||
220V DC Input | 4.5A | 9A | 13.5A | 18A | 22.5A | 27A | 36A | 45.5A | ||
AC by-pass | Allowable by-pass voltage | 170~270VAC | ||||||||
input | (Vac) | |||||||||
Rate input current(A) | 4.5A | 9.1A | 13.6A | 18.2A | 22.7A | 27.2A | 36.3A | 45.4A | ||
By-pass conversion time | ≤5ms | |||||||||
(ms) | ||||||||||
AC output | Rated capacity(VA) | 1KVA | 2KVA | 3KVA | 4KVA | 5KVA | 6KVA | 8KVA | 10KVA | |
Rated output power(W) | 800W | 1600W | 2400W | 3200W | 4000W | 4800W | 5600W | 7000W | ||
Output voltage | 220Vac ( ± 10%V Adjustable LCD Display ) | |||||||||
Output frequency | 50-60Hz ( Auto sync with bypass input ) | |||||||||
Rated output current | 3.6A | 7.3A | 11.0A | 14.5A | 18.2A | 21.8A | 25.4A | 31.8A | ||
Output voltage precision(V) | 220Vac ± 1.5% | |||||||||
Output frequency precision(Hz) | 50Hz ± 0.1% or 60Hz ± 0.1% | |||||||||
Waveform | Pure sine wave | |||||||||
Total harmonic distortion(THD) | ≤3% ( linear load ) | |||||||||
Dynamic response time | Dynamic response time: <5% Vnom for load change 0% to 100%,transient time <5 ms | |||||||||
Power factor( PF ) | >0.8 | >0.7 | ||||||||
Overload capacity | 101%~120% load/continue 60s; 121%~150% load/continue 10s | |||||||||
Inversion efficiency | ≥85% (80% liner load) | |||||||||
By-pass conversion time(ms) | ≤ 5ms | |||||||||
Working environment | Dielectric strength | 1500Vac/10mA/60s | ||||||||
Noise ( 1m ) | < 55dB | < 60dB | < 55dB | |||||||
Operating environment | -20°C~+50°C | |||||||||
temperature | ||||||||||
Humidity | 0~90%, no moisture condensation | |||||||||
Operating altitude ( m ) | ≤ 2000m | |||||||||
Indication | LCD display | Input and output voltage, frequency, output current, temperature, percentage, etc. | ||||||||
Inverter status | Normal mains, normal inversion, battery under-voltage and output overload. |
Technical Data(110VAC output)
Technical Data (110VAC OUTPUT): | ||||||||
MODEL(LV) | RMI1000 | RMI2000 | RMI3000 | RMI4000 | RMI5000 | RMI6000 | ||
24V Allowable range of input DC voltage | Cutoff voltage: ≤ 20Vdc, or ≥30Vdc Startup voltage: 22Vdc-28Vdc | |||||||
48V Allowable range of input DC voltage | Cutoff voltage: ≤ 40Vdc, or ≥60Vdc Startup voltage: 45.5Vdc-57Vdc | |||||||
110V Allowable range of input DC voltage | Cutoff voltage: ≤ 90Vdc, or ≥135Vdc Startup voltage: 104Vdc-131Vdc | |||||||
220V Allowable range of input DC voltage | Cutoff voltage: ≤ 180Vdc, or ≥275Vdc Startup voltage: 208Vdc-260Vdc | |||||||
24V DC Input | Maximum current | 42A | 83A | 125A | - | - | - | |
48V DC Input | 21A | 42A | 63A | 83A | 104A | 125A | ||
110V DC Input | 9A | 18A | 27A | 36A | 45A | 55A | ||
220V DC Input | 4.5A | 9A | 13.5A | 18A | 22.5A | 27A | ||
AC by-pass input | Allowable by-pass voltage (Vac) | 85~135VAC | ||||||
Rate input current(A) | 9A | 18A | 27A | 36.5A | 45.5A | 54.5A | ||
By-pass conversion time (ms) | ≤5ms | |||||||
AC output | Rated capacity(VA) | 1KVA | 2KVA | 3KVA | 4KVA | 5KVA | 6KVA | |
Rated output power(W) | 800W | 1600W | 2400W | 3200W | 4000W | 4800W | ||
Output voltage | 110Vac ( ± 5V Adjustable LCD Display ) | |||||||
Output frequency | 50-60Hz ( Auto sync with bypass input ) | |||||||
Rated output current | 7.2A | 14.4A | 21.8A | 29A | 36.3A | 43.6A | ||
Output voltage precision(V) | 110Vac ± 1.5% | |||||||
Output frequency precision(Hz) | 50Hz ± 0.1% or 60Hz ± 0.1% | |||||||
Waveform | Pure sine wave | |||||||
Total harmonic distortion(THD) | ≤3% ( linear load ) | |||||||
Dynamic response time | Dynamic response time: <5% Vnom for load change 0% to 100%,transient time <5 ms | |||||||
Power factor( PF ) | >0.8 | >0.7 | ||||||
Overload capacity | 101%~120% load/continue 60s; 121%~150% load/continue 10s | |||||||
Inversion efficiency | ≥85% (80% liner load) | |||||||
By-pass conversion time(ms) | ≤ 5ms | |||||||
Working environment | Dielectric strength | 1500Vac/10mA/60s | ||||||
Noise ( 1m ) | < 55dB | < 60dB | ||||||
Operating environment | -20°C~+50°C | |||||||
temperature | ||||||||
Humidity | 0~90%, no moisture condensation | |||||||
Operating altitude ( m ) | ≤ 2000m | |||||||
Indication | LCD display | Input and output voltage, frequency, output current, temperature, percentage, etc. | ||||||
Inverter status | Normal mains, normal inversion, battery under-voltage and output overload. |
Why us? | |
Reasons you would prefer to buy this power supply products from us | |
Service | RMA(24/7 pre-sales and after-sales support),OEM,ODM |
Quality | Highly reliable quality guaranteed by Varta production equipment, German technology, European raw materials |
Warranty | Standard 2 years, 5+ years upon request |
Price | Competitive factory Price! Cut down the cost you paid to the middle man |
Professional | Founded in 1985, 30+ years battery manufacturing experience |
Production capacity | 3,500,000KVAh per year |
Reliable | Two R&D centers; Three major production bases; Global 500+ dealers/ agents; Global 100+ offices; Business coverage 65+ countries around the world |
Shipping & Payment | |
Payment | T/T, L/C , Cash, Western Union etc.(flexible payment term can be discussed) |
Port | Normally Shenzhen China (any sea port upon request) |
Delivery | By sea/air/trian/truck transportation |
Delivery time | Normally 4 weeks ex factory excluding shipping. |
Packing: | Pack in carton box then pallet (wooden box) |