Product Description
125V 100A Lead Acid, Li-ion, Lithium battery charger for Industrial Power Supply.
The EverExceed uXcel range industrial battery charger is the flagship charger of EverExceed Industrial Power solutions. It integrates proven design topology with the latest advanced digital control technology to control the thyristor bridge rectifier and provides the most reliable and trouble-free performance in any electrical and industrial environments.
Features
Key Features:
>Flexible maintenance and Reduced MTTR-The design make it easy for front-access to all vital modules modules of the charger
>Versatile constant voltage and constant current charging modes
>Smart communication and Remote Monitoring through isolated RS232, RS485, Ethernet. Full data logging
>Long design life up to 20+years-system design life up to 20+ years in continuous operation under the condition of appropriate maintenance
>Enhanced Robustness - Mechanical design to withstand vertical and horizontal acceleration stress up to 0.5g as standard
Detailed Photos
Product Parameters
INPUT |
AC voltage |
|
·Single phase |
1×230V(220,240) |
·Three phase |
3×400V(380,415) |
Input voltage tolerance |
±10% |
Input Wiring |
3 Phase 3 Wirse or 3 Phase 4 Wires |
Input frequecny |
50Hz(60Hz) |
Input frequecny tolerance |
±5% |
Input Protection |
Thermic Magnetic Overcurrent protection via MCCB |
OPTIONS |
Rectifier |
Other input voltage(1×110 to 3×690VAC) |
Harmonic filter for THDi≈15% |
Blocking diode |
Surge and Lightning protections |
Voltage ripple filter |
Bettery |
Battery circuit protection box |
Battery reversed polarity detection |
Battery low-voltage disconnection contactor (LVD) |
Battery room temperature sensor |
Battery cabinet / rack |
Battery monitoring system |
System |
Parallel configurations |
Dropping diodes/DC-DC converter |
Earth fault monitoring |
Internal cabinet lighting |
Anti-condensation heater |
Output breaker |
Front-panel analog meters/digtal meters |
DC distribution |
Temparature compensation |
AC high and AC low alarm/protection |
DC high and DC low alarm/protection |
AC fault alarm |
LED test function |
Mechanical |
Other frame colour |
Up to IP55 external |
Plate thickness |
Specified cabinet identification (tag, nameplate) |
Communication |
Modbus TCP/IP |
modbus RTU(RS485) |
DNP3.0 protocol |
Volt-free contacts |
Transducers 4-20mA |
Remote monitoring |
|
|
OUTPUT |
Nominal DC voltage |
24/48/110/125/220/240/400 |
Output voltage range |
0-1.5×nominal voltage (adjustable) |
Nominal DC current |
10-1500A |
Output current range |
0-1.1×nominal current(adjustable) |
Voltage stability |
±1% in float mode, input within tolerance |
Voltage ripple |
1% RMS(with battery connected) |
Current Limitation |
Battery current limitation can be adjusted |
Filtering |
L-C Filter |
Output Protection |
Short Circuit, NH Fuse and Overvoltage protection |
BATTERY |
Type |
Lead acid or nickel cadmium,
vented or recombination and Lithium battery |
COMMUNICATION |
Communication |
RS232, Modbus RTU |
GENERAL DATA |
Operating temperature |
0 to 50 °C |
Storage temperature |
-20 to +70 °C |
Relative humidity |
< 95 % non condensing |
Operating altitude |
1000 m max without derating |
Cooling |
Fan cooling or Natural cooling according to rating |
Efficiency |
90% according to rating |
External protection |
IP20 |
Noise
(at 1m in front of the unit) |
55 - 65 dB according to rating |
Cabinet color |
RAL 7035 |
Dimensions |
Varying according to ratings & options |
STANDARDS |
IEC60146-1-1:2009 |
Semiconductor converters - Specification of basic requirements |
IEC62040-1:2008+AMD1:2013 |
Uninterruptible power systems (UPS) - Part 1-2: General and safety requirements for UPS in restricted access locations |
IEC62040-2:2006 |
Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements |
IEC61439-1:2011 |
Low voltage switchgear and controlgear assemblies - Part 1: General rules |
IEC60529:1989+ AMD1:1999 |
Degrees of protection provided by enclosures (IP Code) |
IEC60076-11:2004 |
Power transformers - Part 11: Dry type transformers |
European Directives |
Low voltage directive: 2006/95/EC and 2014/35/EU
EMC directive: 2004/108/EC and 2014/30/EU
CE Mark |
|
Application:
- Oil & gas offshore & onshore
- Refining petro chemicals
- Telecom
- Transportation (Rail & Aeronautic)
- Power generation, transmission & distribution
Cases
Recent projects:
Our factory
FAQ:
Q1: Are your factory or trading company?
A: We are professional battery manufacturer with our own factory and brand. We provide all kinds of OEM/ODM services for clients, can produce by your samples or technical drawings. We can build the molds and fixtures.
Q2.Can I have a sample order?
A: Yes, we welcome sample order to test and check quality.
Q3: Where can I get the price?
A: We will offer you the best quotation in 12 hours after we get the product specifications such as voltage capacity application etc.
Q4. What is your terms of payment?
A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance.
Q5. How about your delivery time?
A:Generally, it will take 15-30 days after receiving your
advance payment. The specific delivery time depends on the items and the quantity of your order.
Q6. Do you test all your goods before delivery?
A: Yes, We have professional QC team to make sure that the product in good condition before send out the goods.
Q7: How do you make our business long-term and good relationship?
A:1. We keep good quality and competitive price to ensure our customers benefit ;
2. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.