Power Backup Single Phase Everexceed Data Center UPS Rack Pl3 RM1kl

Product Details
Customization: Available
Phase: Single Phase
Type: Standby

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
53
Year of Establishment
2010-04-27
  • Power Backup Single Phase Everexceed Data Center UPS Rack Pl3 RM1kl
  • Power Backup Single Phase Everexceed Data Center UPS Rack Pl3 RM1kl
Find Similar Products

Basic Info.

Model NO.
PL3 RM3KL
Application
Communication
Classification
Power Backup
Standby Time
Long-acting Machine
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Centralized Model
Brand
Everexceed
Color
Black
Battery Type
Lead Acid, Lithium
Certificates
CE / IEC
Transport Package
Carton Box or Wooden Pallets
Specification
190*374*336mm
Trademark
EverExceed
Origin
Shenzhen, China
HS Code
8504402000
Production Capacity
10000

Product Description

High Performance Power Backup Everexceed 1kw 3kw 100/110/115/120/127VAC High Frequency UPS Rack Mounted.

Product introduction:

1-3KVA PL3 RM Series High Frequency Online UPS

1KVA/ 2KVA/ 3KVA module, 100/110/115/120/127VAC, 1:1

 

PowerLead3 series power supply adopts online double conversion design and digital control technology and it features high input and output power factor, self-adaptive output frequency according to input frequency,intelligent battery management and excellent network management.


Power Backup Single Phase Everexceed Data Center UPS Rack Pl3 RM1kl
  • True online double-conversion technology
  • Automatic battery charging on/ off mode
  • Wide input voltage range and stable power supply
  • Lighting and surge protection extends battery lifetime
  • LCD display
  • DSP technology
  • Advanced PFC technology, input PF>99%
  • Cold start
  • Smart RS232 port with monitoring software
  • Smart slot for mission critical applications
Technical specifications:
MODEL
(Low voltage version)
PL3 RM1KS PL3 RM1KL PL3 RM2KS PL3 RM2KL PL3 RM3KS PL3 RM3KL
Capacity 1kVA/1kW 1kVA/1kW 2kVA/2kW 2kVA/2kW 3kVA/3kW 3kVA/3kW
Phase 1 Phase in/1 Phase out
INPUT
Nominal Voltage 100/110/115/120/127VAC (L-N Voltage), L+N+PE
Input Voltage Range 85~155VAC (L-N Voltage)@100%load; 85~55VAC, linearly derating from 100% to 50% load
Input Frequency Range 50/60±6Hz
Input Power Factor >0.99
Input Current Distortion (THDi) <4%
Bypass Voltage Range -40%~20% of nominal voltage, adjustable  
OUTPUT
Nominal Votage 100/110/115/120/127VAC (L-N Voltage), L+N+PE
Voltage Regulation ± 1 %
Nominal Frequency 50/60Hz, adjustable 
Output Frequency Line Mode:50/60±1/2/3/4/5/6Hz , adjustable ; Battery Mode: 50/60±0.001 Hz
Output Power Factor 1
Output Voltage Distortion   (THDu) ≤3%@linear load; ≤5%@non-linear load
Transfer Time
Line mode to Battery mode, 0ms; Inverter to Bypass, 4ms (Synchronized);
Bypass to Inverter, 4ms(Synchronized); ECO to Battery Mode, 6ms (Typical Time)
Crest Ratio 3:1
Overload Capacity
 (Line Mode)
10 min @ 102%~110% load;
1 min @ 110%~130% load;
10s @130%~150% load;
200 ms @ >150% load
Overload Capacity               (Battery Mode)
1 min @ 102%~110% load;
10s @ 110%~130% load;
3s @130%~150% load;
200 ms @ >150% load
Overload Capacity                (Bypass Mode) Depending the input breaker (20A) Depending the input breaker (20A) Depending the input breaker (40A) Depending the input breaker (40A) Depending the input breaker (40A) Depending the input breaker (40A)
Output Short Circuit Protection Line Mode: Current limitation; Battery Mode: Current limitation; Bypas Mode: Breaker
BATTERY
Battery Type Sealed Lead Acid Maintanance Free (VRLA)
Nominal Voltage 24VDC 36VDC 48VDC 72VDC 72VDC 96VDC
Charging Voltage Floating Charge, 2.25V/cell; Boost Charge, 2.35V/cell
Battery Number&Capacity 2 pcs, 12V/9Ah External 4 pcs, 12V/9Ah External 8 pcs, 12V/9Ah External
Charging Current 1A 1~12A, adjustable  1A 1~12A, adjustable  1A 1~12A, adjustable 
Charging Mode Two Satges (CC/Floating) or Three Stages (CC/CV/Floating, settable)
Typical Recharge Time 9 hours recharge to 90% Depending on the capacity of external batteries 9 hours recharge to 90% Depending on the capacity of external batteries 9 hours recharge to 90% Depending on the capacity of external batteries
Battery Protection
Battery Leakage<500µA, Over Voltage Protection, Under Voltage Protection, Over Current Protection;
Battery Deep Discharge Protection
EFFICIENCY
Line Mode  93.5% (Max) 93.5% (Max)
Battery Mode 89.5% (Max) 90.5% (Max) 92.5% (Max) 93.5% (Max) 92.5% (Max) 93.5% (Max)
ECO Mode 98%
INDICATORS
LCD Panel UPS status, Battery Level, Load Level, Input/Outpt/Battery Voltage, Fault&Alarm Code
Audible Alarm Utility Failure, Battery Voltage Low, Overload, System Fault
MANAGEMENT
Interface RS232 ,USB, EPO Port, SNMP Card (Optional), Relay Card (Optional)
ENVIRONMENT
Operating Temperature 0~40ºC
Operating Humidity 0~95% RH, non-condensing
Storage Temperature -15~60ºC (Battery: 0-40ºC)
Altitude <1000m, derating 1% per 100m from 1000~ 2000m
Noise (1Meter Away) <50dB
PHYSICAL
Dimension
(W*D*H, unit:mm)
440*425*86 440*588*86 440*470*86 440*733*86 440*470*86
Net Weight (kg) 9/11.3 4.5 19/23.6 10 25/29.6 11
Color Black ( RAL9004)
STANDARDS
Safety IEC 62040-1:2017
EMC IEC 62040-2:2018
Performance IEC 62040-3:2011
Battery IEC 60896-22:2004

Applications:
  • IDC(Internet Dater Center)
  • Network
  • Servers and workstations
  • Control system
  • Communication system
  • Office,
Why us?  
Reasons you would prefer to buy this power supply products from us 
Service RMA(24/7 pre-sales and after-sales support),OEM,ODM
Quality Highly reliable quality guaranteed by Varta production equipment, German technology, European raw materials
Warranty Standard 2 years, 5+ years upon request
Price Competitive factory Price! Cut down the cost you paid to the middle man
Professional Founded in 1985, 30+ years battery manufacturing experience
Production capacity 3,500,000KVAh per year
Reliable Two R&D centers;
Three major production bases;
Global 500+ dealers/ agents;
Global 100+ offices;
Business coverage 65+ countries around the world
 
Shipping & Payment
Payment T/T,  L/C , Cash, Western Union etc.(flexible payment term can be discussed)
Port Normally Shenzhen China (any sea port upon request)
Delivery  By sea/air/trian/truck transportation
Delivery time Normally 4 weeks ex factory excluding shipping.
Packing: Pack in carton box then pallet (wooden box)

Power Backup Single Phase Everexceed Data Center UPS Rack Pl3 RM1kl


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier